VOLKSWAGEN GOLF IV

since 1997 of release

Repair and car operation



Foltsvagen Golf 4
+ 1. Maintenance instruction
+ 2. Engine
+ 3. Cooling system
+ 4. Fuel system
+ 5. Exhaust system
- 6. Ventilation and heating system
   6.1. Removal and installation snuffled supply of air
   6.2. Installation of the lever of the central zaslonka
   6.3. Removal and installation of the fan of a heater and additional resistor
   6.4. Removal and installation of cables of management by heating and ventilation system
   - 6.5. Zaslonka regulating temperature of air submitted to salon
      6.5.1. Removal and installation
   6.6. Removal and control unit installation by a heater
   6.7. Ventilation of salon of the car
   6.8. Executive engine of the valve of a retsirkulyatsiya of air
   6.9. Air central air
   6.10. Arms of the compressor of the conditioner
+ 7. Coupling
+ 8. Transmission
+ 9. Suspension brackets and power shafts
+ 10. Steering
+ 11. Wheels and tires
+ 12. Brake system
+ 13. Body
+ 14. Electric equipment and electroschemes



6.5. Zaslonka regulating temperature of air submitted to salon

6.5.1. Removal and installation

GENERAL INFORMATION

Elements of connection of air pipes

1–screw;

2–connecting detail;

3–suited supply of air for forward sitting;

4–arm;

5–facing;

6–screw

Removal

PERFORMANCE ORDER
1. Remove a connecting detail (2) and unscrew an arm (4). Holding facing (5), take a connecting detail (2) in the space direction for feet of the driver (arrow A).
2. Turn the rotary handle of adjustment of temperature against the stop counter-clockwise.
3. Dress a cable (1) on the lever of adjustment of temperature (3). Move the lever (3) against the stop clockwise and, having moved a cover of a cable of management on an arrow (And), fix a cable cover a spring clip (2).
4. Turn the handle of adjustment of temperature from an emphasis against the stop and check that it reaches extreme provisions. Otherwise repeat adjustment.

CABLE, THE MANAGING DIRECTOR OF ZASLONKA IN FOOT / DEFROSTING

Fastening of the cable operating a zaslonka in foot / defrosting

1–management cable;

2–spring clip;

3–lever of distribution of streams of air

PERFORMANCE ORDER
1. Turn the rotary handle of distribution of air against the stop counter-clockwise.
2. Establish the rounded-off tip of a cable of management (1) on the lever (3) and move a tip in the direction of an arrow (And).
3. Move a cover of a cable of management in the arrow direction (C) and fix a cover a spring clip (2), having turned it in the arrow direction (In).
4. Turn the handle of distribution of air from an emphasis against the stop and check that it reaches extreme provisions. Otherwise repeat adjustment.

CABLE, MANAGING DIRECTOR OF THE CENTRAL ZASLONKA

PERFORMANCE ORDER
1. Remove a connecting detail (2) (see fig. Elements of connection of air pipes).
2. Turn the rotary handle of distribution of air against the stop counter-clockwise.
3. Establish the rounded-off tip of a cable of management (2) on the lever of the central zaslonka (1). Move a cover of a cable of management in the direction of an arrow (And) and fix it a spring clip (3).
4. Turn the rotary handle of distribution of air from an emphasis against the stop and thus check, that it reached extreme provisions. Otherwise repeat adjustment.

Further installation

PERFORMANCE ORDER
1. Establish a connecting detail on the canal of supply of air for forward sitting and screw an arm.
2. Establish forward section of the central console.
3. Establish the bottom facing of a steering column.
4. Establish ware boxes.